SIMULATION OF TRANSIENT PROCESS IN DISTRIBUTIVE NETWORKS MIDDLE VOLTAGE (10-35 kV)
Main Article Content
Abstract
A new method of simulation and diagnotic of grounding in distribution networks is exposed and it is defined by the parameters resulting from the transition process. Based on the equivalent scheme of the net in case of a grounding is written algorithm that is used to determine the place of failure of grounding. With the help of MATHLAB 6.5 program-adapted package psbtransient is simulated process and obtained results with regard to the selected parameters of the network to the voltage of 10-35 kV.
Downloads
Article Details
References
Bjelic, S., Aleksic, N., Markovic, N. 2007. Protective earthing in high-voltage equipment, Round table with international participation- Enviroment protection in industrial areas, 19-20. april 2007. Kosovska Mitrovica.
Bjelic, S., Jaksic, U., Markovic, N. 2008, Multi-sliced-level type phase-comparison carrier relaying system for multi-terminal lines, 16th Telecommunications Forum, TELFOR 2008, IEEE Co-organized Conference, Belgrade, Serbia 25-27 November 2008.
Бјелић, С., 2007. Енергетски претварачи у мрежама и инсталацијама, Ниш, Свен.
Bjelic, S., Vujicic, M., Mladenovic, V. 2007. Transformation Highphass Filter to Digital Filter for Obtaining Inverse Component in Electrical Networks, IYCE 2007, Conference Budapest.
Bjelić, S., Krečković, N., Bogićević, Z., Marković N., 2007. Estimation flow current, loss of power and voltage fall down are showing us the usage of PDM KMp,q applicative program in electrical engineering, Session 5, Power distribution system development, Block 4, Methods and Tools, Cired, [online] Available at:<http://www.cired.net/publications/cired2007/pdfs/CIRED2007_0907_paper.pdf> [Accessed 14 June 2014].
Bjelić, S., Marković, N., Jakšić, U., Živanić, J. 2013. Selection of linear filter elements parameters for measuring of voltage and currents components of direct and inverse order, Elektronika, Energetyka, Elektrotechnika, PRZEGLĄD ELEKTROTECHNICZNY, 2013-1a, [online] Available at:<http://www.sigma-not.pl/publikacja-74175-selection-of-linear-filter-elements-parameters-for-measuring-of-voltage-and-currents-components-of-direct-and-inverse-order-przeglad-elektrotechniczny-2013-1a.html>[Accessed 14 June 2014].
Markovic, N., Bjelic, S., Jaksic, U., Bogicevic, Z. 2008. Graphical zero-sequence cut-offs method of determining of fault to earth in electrical lines, 9th Symposium on Neural Network Applications in Electrical Engineering, NEUREL-2008, Faculty of Electrical Engineering, University of Belgrade, pp. 73-76.
Marković, N., Bjelić, S., Živanić, J., Jakšić, U. 2013. Numerical simulation and analytical model of electrical arc impedance in the transient processes, Elektronika, Energetyka, Elektrotechnika, PRZEGLĄD ELEKTROTECHNICZNY, 2013-2a, [online] Available at:<http://www.sigma-not.pl/publikacja-74413-numerical-simulation-and-analytical-model-of-electrical-arc-impedance-in-the-transient-processes-przeglad-elektrotechniczny-2013-2a.html> [Accessed 14 June 2014].
Marković, N., Bjelić, S., Jakšić, U., Vujičić, M. 2010. Development of new measuring systems based on symmetric components in electric networks, Elektronika ir elektrotechnika, Signal technology, Lithuania, [online] Available at: <http://www.ee.ktu.lt/journal/2010/8/13__ISSN_1392-1215_Development%20of%20New%20Measuring%20Systems%20Based%20on%20Symmetric%20Components%20in%20Electric%20Networks.pdf > [Accessed 14 June 2014].